Protection with Motor Circuit Breaker (MCB)
Operating mode: Same as for direct on line starting instead of fuses and thermal relay you can use a motor circuit breaker with thermal and magnetic trips, a simple but at least as effective component. By pressing Start push button the Q2 contactor coil is energized, the motor will start run and maintains itself after the button Start release, by means of auxiliary Q2 contact, the Stop and Emergency Stop buttons. When overload occur Q1 circuit breaker opens, so the motor is stopped.
MCB and contactor calculation
Mcb and contactor Q1, Q2 must be chosen according with your motor rated power that can be found on motor plate. Value for F1 fuse must be at most 1 A.
[:ro]
Protectie cu disjunctor magneto-termic
Modul de operare: la fel ca si in cazul pornirii directe in loc de sigurantele fuzibile si releul termic se utilizeaza un disjunctor magneto-termic, o pornire mai simpla dar cel putin la fel de eficienta. Prin acţionarea butonului Start se energizează bobina contactorului Q2, motorul v-a fi conectat și se automenţine după eliberarea butonului Start prin contactul auxiliar al Q2, butonul Stop si Emergency stop. La suprasarcină se deschide disjunctorul magneto-termic Q1. O atentie deosebita trebuie avuta la conectarea condensatorului si a celor doua bobine ale motorului.
Dimensionarea componentelor
Valorile pentru Q1, Q2 trebuie alese in functie de puterea nominala a motorului in conformitate cu datele de pe placuta cu informatii data de producator . Sigurantele fuzibile F1, pentru partea de comanda pot avea valori de pana la max 10 A.
[:]